Guardian
Impax Security Boards
Impax Security Boards "Pressure Laminated":
Fixing Instructions:
Double Sided Impax Board:
Where the wall to be sheeted is an external wall of the building,
the sheets must be
manufactured from a fibre cement sheet bonded to each side to
a sheet of Zincanneal
of the specified thickness. The sheet will be pressure laminated
in a factory environment
strictly as per manufacturer's quality controlled process. The
purpose of double-sided
sheets in this application is to provide a stable panel, which
will not distort under varying
ambient surface temperatures on either side of the panel.
Single Sided Impax Board:
For internal wall and ceiling linings, Impax Board manufactured
from a single sheet of fibre cement bonded
to a sheet of Zincanneal of specified thickness, may be fixed
direct to timber or metal framing. In the
case of an existing wall or ceiling, sheeted with either fibre
cement or plasterboard, single sided Impax
Board may be fixed directly over the existing sheeting
as detailed below, and providing the existing framing structure
will support the additional
weight of the new layer.
Framing:
Recommended framing components are timber and or 1.2mm thick
galvanised metal,
however, variation to this requirement may be granted following
Engineer approved framing design based on application
and system weights per square metre. Wall frame spacing shall be
at 600mm maximum centres, ceiling frame spacing at 400mm maximum
centres, with
additional framing required behind all sheet joints.
Fixings:
For timber:- 10 x 30mm CSK head Type 17 screws.
For Steel:- 10 x 30mm CSK head TEK or Drill Point screws.
Fixing Spacing:
All sheets are to be fixed at 200mm centres around sheet perimeter,
with minimum 15mm edge clearance, and at 400mm
centres through the field of the sheet. All sheets are to
be pre-drilled with a pilot hole 1.0mm oversize of the nominated
screw.
Treatment of Screw Heads:
All screws are to be countersunk and filled with Ciba Geigy
125 Araldite or similar and
sanded flush.
Cutting:
It is recommended that as much cutting as possible be carried
out with a diamond blade
wet cut saw bench in a factory environment. When sheets are
site cut, the edge of the
cut Zincanneal be painted with a metal primer.
Pre-drilled and cut to size sheets can be supplied ex our factory
by arrangement.
Site Storage:
All material delivered to site is to be stored out of the weather
in a dry and level location
until installation is completed.